Insulated flue components

Isolierte Rauchabzugselemente : Insulated flue components
Use of flue components

Twin wall components are suitable for construction of new chimneys.They are installed on the outer or inner wall (chimney enclosed by walls). The components are resistant to high temperatures, condensate and weather conditions. Easily fitted.

Insulated components

Wool insulated flue components consist of three parts.Two pipes and insulation between them.The insulation is mineral wool, which is non combustible and resistant to high temperatures and has a stabile shape. Rubber gaskets and couplings guarantee water and fume tightness.

In addition to wool insulation, flue components are also produced with air insulation. IZO-AIR. Twin wall components are also manufactured with flanges.

-LIM-MONT products related to insulation: Panels (¨sandwich¨), Wool sleeves, Styrofoam


DOWNLOAD THE CERTIFICATE: Insulated flue components

DOWNLOAD THE CERTIFICATE: Single wall flue components


MATERIAL
Type Thickness Code (yyyy)
INOX 316 (W.Nr. - 1.4404 ili 1.4571) s = 0,5 mm 1105
INOX 316 (W.Nr. - 1.4404 ili 1.4571) s = 0,6 mm 1106
INOX 316 (W.Nr. - 1.4404 ili 1.4571) s = 0,7 mm 1107
INOX 316 (W.Nr. - 1.4404 ili 1.4571) s = 1,0 mm 1110
INOX 316 (W.Nr. - 1.4404 ili 1.4571) s = 1,5 mm 1115

MATERIAL D2 (outer wall)
Type Thickness Code (yyyy)
INOX 304 (W.Nr. 1.4301) s = 0,5 mm 1205
INOX 304 (W.Nr. 1.4301) s = 0,6 mm 1206
INOX 304 (W.Nr. 1.4301) s = 0,7 mm 1207
Bakar s = 0,6 mm 6106
Aluminium coated steel plate s = 0,5 mm 2505
Aluminium coated steel plate s = 0,7 mm 2507

Recommended minimum material thickness depends on D1
Diameter D1 (mm) 80-300 350-500

Material thickness

Mu Mv Mu Mv
Recomended s = 0,5 mm s = 0,5 mm s = 0,6 mm s = 0,5 mm
Minimum s = 0,5 mm s = 0,5 mm s = 0,5 mm s = 0,5 mm

Recommended minimum material thickness depends on D1
Diameter D1 (mm) 550 - 750 800 - 1000
Material
Thickness
Mu Mv Mu Mv
Recomended s = 0,7 mm s = 0,6 mm s = 1,0 mm s = 0,7 mm
Minimum s = 0,6 mm s = 0,6 mm s = 0,6 mm s = 0,6 mm
Minimum s = 0,6 mm s = 0,6 mm s = 0,6 mm s = 0,6 mm

Insulation (zz):- mineral wool thickness 25 mm or 50 mm

View the catalog online

Flash paper format

1.0

Download.pdfDownload.pdf

Vrsta dokumenta: Adobe Pdf(pdf)

Veličina: 3713 kb

Datum objave: 21.4.2009.

Isolierte Rauchabzugselemente : Insulated flue components : Insulated flue pipeInsulated flue pipe
Isolierte Rauchabzugselemente : Insulated flue components : Insulated conical reducer  - centricInsulated conical reducer - centric
Isolierte Rauchabzugselemente : Insulated flue components : Insulated  tee fitting 90Insulated tee fitting 90
Isolierte Rauchabzugselemente : Insulated flue components : Insulated 2-segment elbow 45Insulated 2-segment elbow 45
Isolierte Rauchabzugselemente : Insulated flue components : Insulated rain cap  with wind guardInsulated rain cap with wind guard
Isolierte Rauchabzugselemente : Insulated flue components : Insulated Super cap Insulated Super cap
Isolierte Rauchabzugselemente : Insulated flue components : lnsulated boxlnsulated box